Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

show chassis fabric faults recovery-actions

Syntax

Description

Display the last 64 recovery actions related to a fabric null route condition.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis fabric faults recovery-actions command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis fabric faults recovery-actions Output Fields

Field Name

Field Description

Fault Name

The name of fault detected. The fault name appears in a message such as:

CLOS LINK ERROR detected on F2S or F13 slot slot number xf chip chip number and Link Number link number

Recovery Start Time

The time when recovery actions were initiated.

Recovery Action

The recovery action that was used to recover from the mentioned fault. Recovery options depend on the type of faults and can include:

  • SFC SIB Reboot: The SFC SIB was rebooted.

  • LCC SIB Reboot: The LCC SIB was rebooted.

  • FPC Reboot: The FPC was rebooted.

  • Destination Reprogramming: Reenabling the data flow between Packet Forwarding Engines.

  • Interchassis Link Retraining: Retraining of optical links between an LCC SIB and an SFC SIB.

Sample Output

show chassis fabric faults recovery-actions

Release Information

Command introduced in Junos OS Release 14.2.