show interfaces fabric
Syntax
show interfaces fabric <interface-name> <brief | detail | extensive | terse> <descriptions> <media> <routing-instance (all | instance-name)> <snmp-index snmp-index> <statistics>
Description
Display status information about the specified fabric interface.
Options
interface-name | (QFabric systems only) Either the serial number or the alias of the QFabric switch component, such as a Node device, Interconnect device, or QFabric infrastructure. The name can contain a maximum of 128 characters and not contain any colons. |
brief | detail | extensive | terse | (Optional) Display the specified level of output. |
descriptions | (Optional) Display interface description strings. |
media | (Optional) Display media-specific information about network interfaces. |
routing-instance (all | instance-name) | (Optional) Display all routing instances or the name of an individual routing instance. |
snmp-index snmp-index | (Optional) Display information for the specified SNMP index of the interface. |
statistics | (Optional) Display static interface statistics. |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show interfaces fabric
command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
Level of Output |
---|---|---|
Physical Interface | ||
Physical interface |
Name of the physical interface. |
All levels |
Enabled |
State of the interface. |
All levels |
Type |
Physical interface type; for example, Ethernet. |
All levels |
Interface index |
Index number of the physical interface, which reflects its initialization sequence. |
detail extensive none |
SNMP ifIndex |
SNMP index number for the physical interface. |
detail extensive none |
Link-level type |
Encapsulation being used on the physical interface. |
All levels |
MTU |
Maximum transmission unit size on the physical interface. |
All levels |
Clocking |
Reference clock source. |
detail |
Speed |
Speed at which the interface is running. |
All levels |
Duplex |
Duplex mode of the interface, either Full-Duplex or Half-Duplex. |
All levels |
MAC-REWRITE Error |
Specifies if the encapsulation of the packet has been changed. |
none |
BPDU Error |
Specifies if a BPDU has been received on a blocked interface. |
none |
Loopback |
Loopback status: Enabled or Disabled. If loopback is enabled, type of loopback: Local or Remote. |
All levels |
Source filtering |
Source filtering status: Enabled or Disabled. |
All levels |
Flow control |
Flow control status: Enabled or Disabled. This field is only displayed if asymmetric flow control is not configured. |
All levels |
Device flags |
Information about the physical device. |
All levels |
Interface flags |
Information about the interface. |
All levels |
CoS queues |
Number of CoS queues configured. |
detail extensive none |
Hold-Times |
Current interface hold-time up and hold-time down, in milliseconds. |
detail |
Current address |
Configured MAC address. |
detail extensive none |
Hardware address |
Hardware MAC address. |
detail extensive none |
Last flapped |
Date, time, and how long ago the interface went from down to up. The format is Last flapped: year-month-day hour:minute:second:timezone (hour:minute:second ago). For example, Last flapped: 2008–01–16 10:52:40 UTC (3d 22:58 ago). |
detail extensive none |
Statistics last cleared |
Date, time, and how long ago the statistics for the interface were cleared. The format is Statistics last cleared: year-month-day hour:minute:second:timezone (hour:minute:second ago). For example, 2010-05-17 07:51:28 PDT (00:04:33 ago). |
detail extensive |
Traffic statistics |
Number and rate of bytes and packets received and transmitted on the physical interface.
Note:
The bandwidth bps counter is not enabled. |
detail extensive |
IPv6 transit statistics |
If IPv6 statistics tracking is enabled, number of IPv6 bytes and packets received and transmitted on the logical interface:
Note:
The bandwidth bps counter is not enabled. |
detail extensive |
Input errors |
Input errors on the interface. The following paragraphs explain the counters whose meaning might not be obvious:
|
extensive |
Output errors |
Output errors on the interface. The following paragraphs explain the counters whose meaning might not be obvious:
|
extensive |
Egress queues |
Total number of egress queues supported on the specified interface. |
detail extensive |
Queue counters |
CoS queue number and its associated user-configured forwarding class name.
|
detail extensive |
Input rate |
Input rate in bits per second (bps) and packets per second (pps). |
None specified |
Output rate |
Output rate in bps and pps. |
None specified |
Active alarms and Active defects |
Ethernet-specific defects that can prevent the interface from passing packets. When a defect persists for a certain amount of time, it is promoted to an alarm. Based on the switch configuration, an alarm can ring the red or yellow alarm bell on the switch, or turn on the red or yellow alarm LED on the craft interface. These fields can contain the value None or Link.
|
detail extensive none |
MAC statistics |
Receive and Transmit statistics reported by the PIC's MAC subsystem.
|
extensive |
Packet Forwarding Engine Configuration |
Information about the configuration of the Packet Forwarding Engine:
|
extensive |
Logical Interface | ||
Item |
Type of QFabric system component being viewed. Possible values include Node group, Interconnect device, Fabric control, Fabric manager, Diagnostic routing engine, and Ungrouped Node device. |
none |
Identifier |
Hardware serial identifier of a QFabric system component. When you configure an alias name for a component, the ID is displayed. |
none |
Connection |
Status of a QFabric system component: either Connected or Disconnected, depending on whether or not the Director software has detected keepalive messages for the listed component. |
none |
Configuration |
Whether or not the configuration for a QFabric system component has been received and installed. The configuration can be Configured, Failed (unsuccessful), Pending (in the process of being written or retried), or Unknown. |
none |
Node group |
Name of the Node groups associated with the QFabric system, and the Node devices assigned to each Node group. The group can be either Connected or Disconnected, depending on whether or not the Director software has detected keepalive messages for the devices in the group. This field also displays the serial ID for the Node group and the status for the Node group. |
none |
Fabric control |
Name of the virtual Junos Routing Engines responsible for route selection within a QFabric system partition. The fabric control Routing Engine can be either Connected or Disconnected, depending on whether or not the Director software has detected keepalive messages for this virtual device. It also displays the identifier and configuration status for the fabric control Routing Engine. |
none |
Logical interface |
Name of the logical interface. |
All levels |
Index |
Index number of the logical interface, which reflects its initialization sequence. |
detail extensive none |
SNMP ifIndex |
SNMP interface index number for the logical interface. |
detail extensive none |
Flags |
Information about the logical interface. If unicast Reverse Path Forwarding (uRPF) is explicitly configured on the specified interface, the uRPF flag appears. If uRPF was configured on a different interface (and therefore is enabled on all switch interfaces) but was not explicitly configured on the specified interface, the uRPF flag does not appear even though uRPF is enabled. |
All levels |
Encapsulation |
Encapsulation method used on the logical interface. |
All levels |
Traffic statistics |
Number and rate of bytes and packets received and transmitted on the physical interface.
Note:
The bandwidth bps counter is not enabled. |
detail extensive |
Local statistics |
Note:
The bandwidth bps counter is not enabled. |
detail extensive |
Transit statistics |
Note:
The bandwidth bps counter is not enabled. |
detail extensive |
protocol-family |
Protocol family configured on the logical interface. If the protocol is inet, the IP address of the interface is also displayed. |
brief |
Generation |
Unique number for use by Juniper Networks technical support only. |
detail extensive |
Route table |
Route table in which the logical interface address is located. For example, 0 refers to the routing table inet.0. |
detail extensive none |
Sample Output
- show interfaces fabric
- show interfaces fabric brief
- show interfaces fabric detail
- show interfaces fabric extensive
- show interfaces fabric terse
- show interfaces fabric device-name
show interfaces fabric
user@switch> show interfaces fabric Item Identifier Connection Configuration Node group BBAK3775 Connected Configured NW-NG-0 Connected Configured P2659-C Connected Configured ptor-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured
show interfaces fabric brief
user@switch> show interfaces fabric brief Physical interface: BBAK0372:fte-0/1/0, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface BBAK0372:fte-0/1/0.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: BBAK0372:fte-0/1/2, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface BBAK0372:fte-0/1/2.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: BBAK0394:fte-0/1/0, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x4000 Logical interface BBAK0394:fte-0/1/0.32768 Flags: SNMP-Traps Encapsulation: ENET2 eth-switch Physical interface: BBAK0394:fte-0/1/2, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x4000 Logical interface BBAK0394:fte-0/1/2.32768 Flags: SNMP-Traps Encapsulation: ENET2 eth-switch Physical interface: BBAK3775:bme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Logical interface BBAK3775:bme0.0 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.1/2 128.0.0.16/2 128.0.32.0/2 tnp 0x10 Logical interface BBAK3775:bme0.1 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.13/2 128.0.130.0/2 Logical interface BBAK3775:bme0.2 Flags: Encapsulation: ENET2 inet 128.0.0.13/8 128.0.130.0/8 169.254.128.13/16 169.254.193.0/16 Physical interface: BBAK3775:qfabric, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Interface flags: SNMP-Traps Logical interface BBAK3775:qfabric.0 Flags: SNMP-Traps Encapsulation: ENET2 inet mpls eth-switch Physical interface: BBAK3775:vcp0, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface BBAK3775:vcp0.32769 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: BBAK3775:vcp1, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface BBAK3775:vcp1.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: BBAK3775:vcp2, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface BBAK3775:vcp2.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: BBAK3775:fte-0/1/0, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface BBAK3775:fte-0/1/0.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: EE3093:fte-0/1/0, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface EE3093:fte-0/1/0.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: EE3093:fte-0/1/2, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface EE3093:fte-0/1/2.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-0/0/0, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-0/0/0.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-0/0/4, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-0/0/4.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-0/0/6, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-0/0/6.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-0/0/13, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-0/0/13.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-0/0/15, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-0/0/15.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-1/0/2, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-1/0/2.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-1/0/7, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-1/0/7.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:fte-1/0/10, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface IC-WS001:fte-1/0/10.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: IC-WS001:bme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Logical interface IC-WS001:bme0.0 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.32.0 --> 0/0 Logical interface IC-WS001:bme0.1 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.7/2 128.0.130.2/2 Logical interface IC-WS001:bme0.2 Flags: Encapsulation: ENET2 inet 128.0.0.7/8 128.0.130.2/8 169.254.128.7/16 169.254.193.1/16 Physical interface: IC-WS001:bme1, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Interface flags: SNMP-Traps Logical interface IC-WS001:bme1.0 Flags: Encapsulation: ENET2 inet 128.0.0.1/2 128.0.0.4/2 128.0.0.16/2 128.0.0.17/2 128.0.0.24/2 128.0.0.25/2 128.0.0.26/2 128.0.0.28/2 128.0.0.29/2 128.0.0.31/2 tnp 0x4 Physical interface: IC-WS001:qfabric, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Interface flags: SNMP-Traps Logical interface IC-WS001:qfabric.0 Flags: SNMP-Traps Encapsulation: ENET2 inet mpls eth-switch Physical interface: IC-WS001:pme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Interface flags: SNMP-Traps Physical interface: IC-WS001:pme1, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Interface flags: SNMP-Traps Physical interface: IC-WS001:pme2, Enabled, Physical link is Down Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Interface flags: SNMP-Traps Physical interface: IC-WS001:pme3, Enabled, Physical link is Down Type: Ethernet, Link-level type: Ethernet, MTU: 1510, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Interface flags: SNMP-Traps Physical interface: IC-WS001:vcp0, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface IC-WS001:vcp0.32769 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: IC-WS001:vcp1, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface IC-WS001:vcp1.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: IC-WS001:vcp2, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface IC-WS001:vcp2.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: IC-WS001:vcp3, Enabled, Physical link is Down Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface IC-WS001:vcp3.32768 Flags: Device-Down LinkAddress 0-0 Encapsulation: ENET2 Physical interface: IC-WS001:vcp4, Enabled, Physical link is Down Type: Ethernet, Link-level type: 70, MTU: 1492, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface IC-WS001:vcp4.32768 Flags: Device-Down LinkAddress 0-0 Encapsulation: ENET2 Physical interface: NW-NG-0:bme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Logical interface NW-NG-0:bme0.0 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.1/2 128.0.0.5/2 128.0.32.0/2 tnp 0x5 Logical interface NW-NG-0:bme0.1 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.9/2 128.0.128.4/2 Logical interface NW-NG-0:bme0.2 Flags: Encapsulation: ENET2 inet 128.0.0.9/8 128.0.128.68/8 169.254.128.9/16 169.254.192.34/16 Physical interface: NW-NG-0:qfabric, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Interface flags: SNMP-Traps Logical interface NW-NG-0:qfabric.0 Flags: SNMP-Traps Encapsulation: ENET2 inet mpls eth-switch Physical interface: NW-NG-0:vcp0, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface NW-NG-0:vcp0.32769 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: NW-NG-0:vcp1, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface NW-NG-0:vcp1.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: P2659-C:bme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Logical interface P2659-C:bme0.0 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.1/2 128.0.0.16/2 128.0.32.0/2 tnp 0x10 Logical interface P2659-C:bme0.1 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.8/2 128.0.130.4/2 Logical interface P2659-C:bme0.2 Flags: Encapsulation: ENET2 inet 128.0.0.8/8 128.0.130.4/8 169.254.128.8/16 169.254.193.2/16 Physical interface: P2659-C:qfabric, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Interface flags: SNMP-Traps Logical interface P2659-C:qfabric.0 Flags: SNMP-Traps Encapsulation: ENET2 inet mpls eth-switch Physical interface: P2659-C:vcp0, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface P2659-C:vcp0.32769 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: P2659-C:vcp1, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface P2659-C:vcp1.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: P2659-C:vcp2, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface P2659-C:vcp2.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: P2659-C:fte-0/1/2, Enabled, Physical link is Up Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 Logical interface P2659-C:fte-0/1/2.32768 Flags: SNMP-Traps 0x0 Encapsulation: ENET2 eth-switch Physical interface: ptor-0:bme0, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1500, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Logical interface ptor-0:bme0.0 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.1/2 128.0.0.17/2 128.0.32.0/2 tnp 0x11 Logical interface ptor-0:bme0.1 Flags: LinkAddress 0-0 Encapsulation: ENET2 inet 128.0.0.16/2 128.0.130.18/2 Logical interface ptor-0:bme0.2 Flags: Encapsulation: ENET2 inet 128.0.0.16/8 128.0.130.18/8 169.254.128.16/16 169.254.193.9/16 Physical interface: ptor-0:qfabric, Enabled, Physical link is Up Type: Ethernet, Link-level type: Ethernet, MTU: 1572, Clocking: Unspecified, Speed: Unspecified Device flags : Present Running Interface flags: SNMP-Traps Logical interface ptor-0:qfabric.0 Flags: SNMP-Traps Encapsulation: ENET2 inet mpls eth-switch Physical interface: ptor-0:vcp0, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1514, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface ptor-0:vcp0.32769 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: ptor-0:vcp1, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface ptor-0:vcp1.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2 Physical interface: ptor-0:vcp2, Enabled, Physical link is Up Type: Ethernet, Link-level type: 70, MTU: 1496, Clocking: Unspecified, Speed: 1000mbps Device flags : Present Running Logical interface ptor-0:vcp2.32768 Flags: LinkAddress 0-0 Encapsulation: ENET2
show interfaces fabric detail
user@switch> show interfaces fabric detail Physical interface: BBAK0372:fte-0/1/0, Enabled, Physical link is Up Interface index: 49165, SNMP ifIndex: 1212678666, Generation: 140 Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 CoS queues : 12 supported, 12 maximum usable queues Hold-times : Up 0 ms, Down 0 ms Current address: 84:18:88:d1:fa:1f, Hardware address: 84:18:88:d1:fa:1f Last flapped : 2012-11-09 21:36:41 UTC (4d 00:23 ago) Statistics last cleared: Never Traffic statistics: Input bytes : 14256654 0 bps Output bytes : 9618986 0 bps Input packets: 90511 0 pps Output packets: 60101 0 pps IPv6 transit statistics: Input bytes : 0 Output bytes : 0 Input packets: 0 Output packets: 0 Egress queues: 12 supported, 5 in use Queue counters: Queued packets Transmitted packets Dropped packets 0 best-effort 0 0 0 3 fcoe 0 0 0 4 no-loss 0 0 0 7 network-cont 0 0 0 8 mcast 0 0 0 Active alarms : None Active defects : None Logical interface BBAK0372:fte-0/1/0.32768 (Index 71) (SNMP ifIndex 1212678667) (Generation 136) Flags: SNMP-Traps 0x0 Encapsulation: ENET2 Traffic statistics: Input bytes : 12450372 Output bytes : 11986557 Input packets: 90510 Output packets: 62750 Local statistics: Input bytes : 12450372 Output bytes : 11986557 Input packets: 90510 Output packets: 62750 Transit statistics: Input bytes : 0 0 bps Output bytes : 0 0 bps Input packets: 0 0 pps Output packets: 0 0 pps Protocol eth-switch, MTU: 0, Generation: 163, Route table: 0
show interfaces fabric extensive
user@switch> show interfaces fabric extensive Physical interface: IC-WS001:fte-0/0/6, Enabled, Physical link is Up Interface index: 49176, SNMP ifIndex: 1209008655, Generation: 155 Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 CoS queues : 12 supported, 12 maximum usable queues Hold-times : Up 0 ms, Down 0 ms Current address: 00:00:00:00:00:06, Hardware address: 00:00:00:00:00:06 Last flapped : 2012-11-13 23:53:30 UTC (00:53:20 ago) Statistics last cleared: Never Traffic statistics: Input bytes : 91179 0 bps Output bytes : 361268221791 952985992 bps Input packets: 590 0 pps Output packets: 2580487185 850880 pps IPv6 transit statistics: Input bytes : 0 Output bytes : 0 Input packets: 0 Output packets: 0 Input errors: Errors: 0, Drops: 0, Framing errors: 0, Runts: 0, Policed discards: 0, L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0, FIFO errors: 0, Resource errors: 0 Output errors: Carrier transitions: 1, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0, FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0 Egress queues: 12 supported, 5 in use Queue counters: Queued packets Transmitted packets Dropped packets 0 fabric_fcset 0 0 0 1 fabric_fcset 0 0 0 2 fabric_fcset 0 0 0 3 fabric_fcset 0 0 0 4 fabric_fcset 0 0 0 5 fabric_fcset 0 0 0 6 fabric_fcset 0 0 0 7 fabric_fcset 0 0 0 8 fabric_fcset 0 2582632925 0 9 fabric_fcset 0 0 0 10 fabric_fcset 0 0 0 11 fabric_fcset 0 0 0 Active alarms : None Active defects : None MAC statistics: Receive Transmit Total octets 91179 361268221791 Total packets 590 2580487185 Unicast packets 590 2580487185 Broadcast packets 0 0 Multicast packets 0 0 CRC/Align errors 0 0 FIFO errors 0 0 MAC control frames 0 0 MAC pause frames 0 0 Oversized frames 0 Jabber frames 0 Fragment frames 0 VLAN tagged frames 0 Code violations 0 MAC Priority Flow Control Statistics: Priority : 0 0 0 Priority : 1 0 0 Priority : 2 0 0 Priority : 3 0 0 Priority : 4 0 0 Priority : 5 0 0 Priority : 6 0 0 Priority : 7 0 0 Packet Forwarding Engine configuration: Destination slot: 0 Direction : Output CoS transmit queue Bandwidth Buffer Priority Limit % bps % usec 0 best-effort 5 2000000000 5 0 low none 3 fcoe 35 14000000000 35 0 low none 4 no-loss 35 14000000000 35 0 low none 7 network-control 5 2000000000 5 0 low none 8 mcast 20 8000000000 20 0 low none Logical interface IC-WS001:fte-0/0/6.32768 (Index 85) (SNMP ifIndex 1209008656) (Generation 150) Flags: SNMP-Traps 0x0 Encapsulation: ENET2 Traffic statistics: Input bytes : 79496 Output bytes : 179860 Input packets: 590 Output packets: 948 Local statistics: Input bytes : 79496 Output bytes : 179860 Input packets: 590 Output packets: 948 Transit statistics: Input bytes : 0 0 bps Output bytes : 0 0 bps Input packets: 0 0 pps Output packets: 0 0 pps Protocol eth-switch, MTU: 0, Generation: 178, Route table: 0
show interfaces fabric terse
user@switch> show interfaces fabric terse Item Identifier Connection Configuration Node group BBAK3775 Connected Configured NW-NG-0 Connected Configured P2659-C Connected Configured ptor-0 Connected Configured Fabric control FC-0 Connected Configured FC-1 Connected Configured
show interfaces fabric device-name
user@switch> show interfaces fabric IC-WS001:fte-0/0/13 Physical interface: IC-WS001:fte-0/0/13, Enabled, Physical link is Up Interface index: 49177, SNMP ifIndex: 1209008767 Link-level type: Ethernet, MTU: 9232, Speed: 40Gbps, Duplex: Full-Duplex, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled Device flags : Present Running Interface flags: SNMP-Traps Internal: 0x0 CoS queues : 12 supported, 12 maximum usable queues Current address: 00:00:00:00:00:0d, Hardware address: 00:00:00:00:00:0d Last flapped : 2012-11-13 23:55:15 UTC (00:55:38 ago) Input rate : 0 bps (0 pps) Output rate : 0 bps (0 pps) Active alarms : None Active defects : None Logical interface IC-WS001:fte-0/0/13.32768 (Index 86) (SNMP ifIndex 1209008768) Flags: SNMP-Traps 0x0 Encapsulation: ENET2 Input packets : 748 Output packets: 954 Protocol eth-switch, MTU: 0
Release Information
Command introduced in Junos OS Release 12.3.