retry-interval (Chassis Cluster)

date_range 19-Nov-23

Syntax

content_copy zoom_out_map
retry-interval interval;

Hierarchy Level

content_copy zoom_out_map
[edit chassis cluster redundancy-group group-number  ip-monitoring ]

Description

Specify the ping packet send frequency (in seconds) for each IP address monitored by the redundancy group.

In the IP address monitoring, you can configure redundancy groups to monitor upstream resources by pinging specific IP addresses that are reachable through redundant Ethernet interfaces on either node in a cluster. In this configuration, the retry interval determines the ping interval for each IP address monitored by the redundancy group and the retry count sets the number of allowed consecutive ping failures for each IP address monitored by the redundancy group.

(See retry-count (Chassis Cluster) for a related IP address monitoring configuration variable.)

Options

interval—Pause time (in seconds) between each ping sent to each IP address monitored by the redundancy group.

  • Default: 1

  • Range: 1-30

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.1.