show chassis cluster interfaces
Syntax
show chassis cluster interfaces
Description
Display the status of the control interface in a chassis cluster configuration.
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis cluster interfaces
command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
---|---|
|
State of the chassis cluster control interface: |
|
|
|
State of
the fabric interface: |
|
|
|
|
|
|
|
|
Sample Output
show chassis cluster interfaces (SRX5000 line devices with RE3)
user@host> show chassis cluster interfaces Control link status: Down Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 ixlv0 Down Enabled Disabled 1 igb0 Down Enabled Disabled Fabric link status: Down Fabric interfaces: Name Child-interface Status Security (Physical/Monitored) fab0 fab0 Redundant-ethernet Information: Name Status Redundancy-group reth0 Down Not configured reth1 Down Not configured reth2 Down Not configured reth3 Down Not configured reth4 Down Not configured Redundant-pseudo-interface Information: Name Status Redundancy-group lo0 Up 0
Sample Output
show chassis cluster interfaces (SRX5000 line devices with RE2)
user@host> show chassis cluster interfaces Control link status: Up Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 em0 Up Disabled Disabled 1 em1 Down Disabled Disabled Fabric link status: Up Fabric interfaces: Name Child-interface Status Security (Physical/Monitored) fab0 xe-1/0/3 Up / Down Disabled fab0 fab1 xe-7/0/3 Up / Down Disabled fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up 1 reth1 Up 2 reth2 Down Not configured reth3 Down Not configured reth4 Down Not configured reth5 Down Not configured reth6 Down Not configured reth7 Down Not configured reth8 Down Not configured reth9 Down Not configured reth10 Down Not configured reth11 Down Not configured Redundant-pseudo-interface Information: Name Status Redundancy-group lo0 Up 1 Interface Monitoring: Interface Weight Status Redundancy-group ge-0/1/9 100 Up 0 ge-0/1/9 100 Up
Sample Output
show chassis cluster interfaces
user@host> show chassis cluster interfaces
The following output is specific to fabric monitoring failure:
Control link status: Up Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 em0 Up Disabled Disabled Fabric link status: Down Fabric interfaces: Name Child-interface Status Security (Physical/Monitored) fab0 ge-0/0/2 Down / Down Disabled fab0 fab1 ge-9/0/2 Up / Up Disabled fab1 Redundant-pseudo-interface Information: Name Status Redundancy-group lo0 Up 0
Sample Output
show chassis cluster interfaces (SRX5400, SRX5600, and SRX5800 Devices with SRX5000 line SRX5K-SCB3 [SCB3] with Enhanced Midplanes and SRX5K-MPC3-100G10G [IOC3] or SRX5K-MPC3-40G10G [IOC3])
user@host> show chassis cluster interfaces
The following output is specific to SRX5400, SRX5600, and SRX5800 devices in a chassis cluster cluster, when the PICs containing fabric links on the SRX5K-MPC3-40G10G (IOC3) are powered off to turn on alternate PICs. If no alternate fabric links are configured on the PICs that are turned on, RTO synchronous communication between the two nodes stops and the chassis cluster session state will not back up, because the fabric link is missing.
Control link status: Up Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 em0 Up Disabled Disabled 1 em1 Down Disabled Disabled Fabric link status: Down Fabric interfaces: Name Child-interface Status Security (Physical/Monitored) fab0 <<< fab child missing once PIC off lined Disabled fab0 fab1 xe-10/2/7 Up / Down Disabled fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up Not configured reth1 Down 1 Redundant-pseudo-interface Information: Name Status Redundancy-group lo0 Up 0
Sample Output
show chassis cluster interfaces (vSRX Virtual Firewall)
user@host> show chassis cluster interfaces
The following output is specific to view control link status with internal SAs.
Control link status: Up Control interfaces: Index Interface Status Internal SA 305 0 em0 Up enabled 306 1 em1 Down enabled
Sample Output
show chassis cluster interfaces (SRX1500 Devices)
user@host> show chassis cluster interfaces
Check chassis cluster control link and fabric link status.
Control link status: Up Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 em0 Up Disabled Disabled Fabric link status: Up Fabric interfaces: Name Child-interface Status Security (Physical/Monitored) fab0 ge-0/0/11 Up / Up Disabled fab0 fab1 ge-7/0/11 Up / Up Disabled fab1 Redundant-ethernet Information: Name Status Redundancy-group reth0 Up 1 reth1 Up 1 reth2 Down Not configured reth3 Down Not configured reth4 Down Not configured Redundant-pseudo-interface Information: Name Status Redundancy-group lo0 Up 1 Interface Monitoring: Interface Weight Status Redundancy-group (Physical/Monitored) ge-0/0/4 255 Up / Up 1 ge-7/0/4 255 Up / Up 1 ge-0/0/2 255 Up / Up 1 ge-7/0/2 255 Up / Up 1
command-name
After you disable control link:
Control link status: Admin Down Control interfaces: Index Interface Monitored-Status Internal-SA Security 0 em0 Down Disabled Disabled
Sample Output
Release Information
Command modified in Junos OS Release 9.0. Output changed to support dual control ports in Junos OS Release 10.0. Output changed to support control interfaces in Junos OS Release 11.2. Output changed to support redundant pseudo interfaces in Junos OS Release 12.1X44-D10. For SRX5000 line devices, output changed to support the internal security association (SA) option in Junos OS Release 12.1X45-D10. Output changed to support MACsec status on control and fabric interfaces in Junos OS Release 15.1X49-D60. For vSRX Virtual Firewall, output changed to support the internal security association (SA) option in Junos OS Release 19.4R1.