date_range 19-Nov-23

Syntax

content_copy zoom_out_map
         show chassis cluster interfaces       

Description

Display the status of the control interface in a chassis cluster configuration.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis cluster interfaces command. Output fields are listed in the approximate order in which they appear.

Table 1: show chassis cluster interfaces Output Fields

Field Name

Field Description

Control link status

State of the chassis cluster control interface: up or down.

Control interfaces

  • Index—Index number of the chassis cluster control interface.

  • Interface—Name of the chassis cluster control interface. The control interface names differ based on the routing engine. For RE2, the control interfaces are displayed as em0 and em1 and for RE3, the control interfaces are displayed as ixlv0 and igb0.

  • Monitored-Status—Monitored state of the interface: up or down.

  • Internal SA—State of the internal SA option on the chassis cluster control link: enabled or disabled.

    Note:

    This field is available only on SRX5000 line devices.

  • Security—State of MACsec on chassis cluster control interfaces.

Fabric link status

State of the fabric interface: up or down.

Fabric interfaces

  • Name—Name of the fabric interface.

  • Child-interface—Name of the child fabric interface.

  • Status—State of the interface: up or down.

  • Security—State of MACsec on chassis cluster fabric interfaces.

Redundant-ethernet Information

  • Name—Name of the redundant Ethernet interface.

  • Status—State of the interface: up or down.

  • Redundancy-group—Identification number (1–255) of the redundancy group associated with the redundant Ethernet interface.

Redundant-pseudo-interface Information

  • Name—Name of the redundant pseudointerface.

  • Status—State of the redundant pseudointerface: up or down.

  • Redundancy-group—Identification number (1–255) of the redundancy group associated with the redundant pseudointerface.

Interface Monitoring

  • Interface—Name of the interface to be monitored.

  • Weight—Relative importance of the interface to redundancy group operation.

  • Status—State of the interface: up or down.

  • Redundancy-group—Identification number of the redundancy group associated with the interface.

Sample Output

show chassis cluster interfaces (SRX5000 line devices with RE3)

content_copy zoom_out_map
user@host> show chassis cluster interfaces
Control link status: Down

Control interfaces:
    Index   Interface   Monitored-Status   Internal-SA   Security
    0       ixlv0       Down               Enabled       Disabled
    1       igb0        Down               Enabled       Disabled

Fabric link status: Down

Fabric interfaces:
    Name    Child-interface    Status                    Security
                               (Physical/Monitored)
    fab0
    fab0

Redundant-ethernet Information:
    Name         Status      Redundancy-group
    reth0        Down        Not configured
    reth1        Down        Not configured
    reth2        Down        Not configured
    reth3        Down        Not configured
    reth4        Down        Not configured

Redundant-pseudo-interface Information:
    Name         Status      Redundancy-group
    lo0          Up          0

Sample Output

show chassis cluster interfaces (SRX5000 line devices with RE2)

content_copy zoom_out_map
user@host> show chassis cluster interfaces  
Control link status: Up


 Control interfaces:
    Index   Interface   Monitored-Status   Internal-SA   Security
    0       em0         Up                 Disabled      Disabled
    1       em1         Down               Disabled      Disabled
Fabric link status: Up

Fabric interfaces:
    Name    Child-interface    Status                    Security   
                               (Physical/Monitored)
    fab0    xe-1/0/3           Up   / Down               Disabled   
    fab0
    fab1    xe-7/0/3           Up   / Down               Disabled
    fab1

Redundant-ethernet Information:     
    Name         Status      Redundancy-group
    reth0        Up          1                
    reth1        Up          2                
    reth2        Down        Not configured   
    reth3        Down        Not configured   
    reth4        Down        Not configured   
    reth5        Down        Not configured   
    reth6        Down        Not configured   
    reth7        Down        Not configured   
    reth8        Down        Not configured   
    reth9        Down        Not configured   
    reth10       Down        Not configured   
    reth11       Down        Not configured   

Redundant-pseudo-interface Information:
    Name        Status       Redundancy-group
     lo0          Up               1

Interface Monitoring:
    Interface         Weight    Status    Redundancy-group
    ge-0/1/9          100       Up        0   
    ge-0/1/9          100       Up 

Sample Output

show chassis cluster interfaces

content_copy zoom_out_map
user@host> show chassis cluster interfaces

The following output is specific to fabric monitoring failure:

content_copy zoom_out_map
Control link status: Up

Control interfaces: 
    Index   Interface    Monitored-Status   Internal-SA  Security
    0       em0         Up                 Disabled     Disabled 

Fabric link status: Down

Fabric interfaces: 
    Name    Child-interface    Status							Security
                               (Physical/Monitored)
    fab0    ge-0/0/2           Down / Down					Disabled
    fab0   
    fab1    ge-9/0/2           Up   / Up  					Disabled
    fab1   
   
Redundant-pseudo-interface Information:
    Name         Status      Redundancy-group
    lo0          Up          0

Sample Output

show chassis cluster interfaces (SRX5400, SRX5600, and SRX5800 Devices with SRX5000 line SRX5K-SCB3 [SCB3] with Enhanced Midplanes and SRX5K-MPC3-100G10G [IOC3] or SRX5K-MPC3-40G10G [IOC3])

content_copy zoom_out_map
user@host> show chassis cluster interfaces

The following output is specific to SRX5400, SRX5600, and SRX5800 devices in a chassis cluster cluster, when the PICs containing fabric links on the SRX5K-MPC3-40G10G (IOC3) are powered off to turn on alternate PICs. If no alternate fabric links are configured on the PICs that are turned on, RTO synchronous communication between the two nodes stops and the chassis cluster session state will not back up, because the fabric link is missing.

content_copy zoom_out_map
Control link status: Up
 
Control interfaces:
    Index   Interface   Monitored-Status   Internal-SA   Security
    0       em0         Up                 Disabled   	 Disabled
    1       em1         Down               Disabled   	 Disabled
 
Fabric link status: Down
 
Fabric interfaces:
    Name    Child-interface    Status 							Security
                               (Physical/Monitored)
    fab0     <<< fab child missing once PIC off lined    Disabled
    fab0  
    fab1    xe-10/2/7          Up   / Down               Disabled
    fab1  
 
Redundant-ethernet Information:    
    Name         Status      Redundancy-group
    reth0        Up          Not configured  
    reth1        Down        1               
  
Redundant-pseudo-interface Information:
    Name         Status      Redundancy-group
    lo0          Up          0

Sample Output

show chassis cluster interfaces (vSRX Virtual Firewall)

content_copy zoom_out_map
user@host> show chassis cluster interfaces

The following output is specific to view control link status with internal SAs.

content_copy zoom_out_map
Control link status: Up

Control interfaces: 
 Index     Interface           Status         Internal SA
 305
      0       em0              Up              enabled 
306
      1       em1              Down            enabled

Sample Output

show chassis cluster interfaces (SRX1500 Devices)

content_copy zoom_out_map
user@host> show chassis cluster interfaces

Check chassis cluster control link and fabric link status.

content_copy zoom_out_map
Control link status: Up

Control interfaces:
    Index   Interface   Monitored-Status   Internal-SA   Security
    0       em0         Up                 Disabled      Disabled

Fabric link status: Up

Fabric interfaces:
    Name    Child-interface    Status                    Security
                               (Physical/Monitored)
    fab0    ge-0/0/11          Up   / Up                 Disabled
    fab0
    fab1    ge-7/0/11          Up   / Up                 Disabled
    fab1

Redundant-ethernet Information:
    Name         Status      Redundancy-group
    reth0        Up          1
    reth1        Up          1
    reth2        Down        Not configured
    reth3        Down        Not configured
    reth4        Down        Not configured

Redundant-pseudo-interface Information:
    Name         Status      Redundancy-group
    lo0          Up          1

Interface Monitoring:
    Interface         Weight    Status                    Redundancy-group
                                (Physical/Monitored)
    ge-0/0/4          255       Up  /  Up                 1
    ge-7/0/4          255       Up  /  Up                 1
    ge-0/0/2          255       Up  /  Up                 1
    ge-7/0/2          255       Up  /  Up                 1

command-name

After you disable control link:

content_copy zoom_out_map
Control link status: Admin Down

Control interfaces:
    Index   Interface   Monitored-Status   Internal-SA   Security
0       em0         Down                 Disabled      Disabled

Sample Output

Release Information

Command modified in Junos OS Release 9.0. Output changed to support dual control ports in Junos OS Release 10.0. Output changed to support control interfaces in Junos OS Release 11.2. Output changed to support redundant pseudo interfaces in Junos OS Release 12.1X44-D10. For SRX5000 line devices, output changed to support the internal security association (SA) option in Junos OS Release 12.1X45-D10. Output changed to support MACsec status on control and fabric interfaces in Junos OS Release 15.1X49-D60. For vSRX Virtual Firewall, output changed to support the internal security association (SA) option in Junos OS Release 19.4R1.

footer-navigation