show chassis fpc (View)
Syntax
show chassis fpc
<detail
<fpc-slot
>| <node (node-id
| local | primary)>> | <node (node-id
| local | primary)> | <pic-status
<fpc-slot
>| <node (node-id
| local | primary)>>
Description
Display status information about the installed Flexible PIC Concentrators (FPCs) and PICs.
Options
none—Display status information for all FPCs.
detail
—(Optional) Display detailed FPC status information.fpc-slot
—(Optional) Display information about the FPC in this slot.node
—(Optional) For chassis cluster configurations, display status information for all FPCs or for the specified FPC on a specific node (device) in the cluster.node-id
—Identification number of the node. It can be 0 or 1.local
—Display information about the local node.primary
—Display information about the primary node.
-
pic-status
—(Optional) Display status information for all FPCs or for the FPC in the specified slot (seefpc-slot
).
Required Privilege Level
view
Output Fields
Table 1 lists the output
fields for the show chassis fpc
command. Output fields
are listed in the approximate order in which they appear.
Field Name |
Field Description |
---|---|
|
Slot number and state. The state can be one of the following conditions:
|
|
Temperature of the air passing by the FPC, in degrees Celsius or in both Celsius and Fahrenheit. |
|
Total percentage of CPU being used by the FPC's processor. |
|
Of the total CPU being used by the FPC's processor, the percentage being used for interrupts. |
|
Total DRAM, in megabytes, available to the FPC's processor. |
|
Percentage of heap space (dynamic memory) being used by the FPC's processor. If this number exceeds 80 percent, there may be a software problem (memory leak). |
|
Percentage of buffer space being used by the FPC's processor for buffering internal messages. |
|
Time when the Routing Engine detected that the FPC was running. |
|
How long the Routing Engine has been connected to the FPC and, therefore, how long the FPC has been up and running. |
|
( |
Sample Output
- show chassis fpc
- show chassis fpc (SRX5600 and SRX5800 devices)
- show chassis fpc (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3)
show chassis fpc
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online -------------------- CPU less FPC -------------------- 1 Online --------------------- Not Usable -------------------- 2 Online -------------------- CPU less FPC --------------------
show chassis fpc (SRX5600 and SRX5800 devices)
user@host> show chassis fpc Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Empty 1 Empty 2 Empty 3 Online 37 3 0 1024 7 42 4 Empty 5 Empty 6 Online 30 8 0 1024 23 30 7 Empty 8 Empty 9 Empty 10 Empty 11 Empty
show chassis fpc (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3)
user@host> show chassis fpc Temp CPU Utilization (%) CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt 1min 5min 15min DRAM (MB) Heap Buffer 0 Online 36 20 0 20 19 19 1024 4 26 1 Online 35 8 0 8 8 8 2048 12 14 2 Online 40 21 0 20 20 20 3584 5 13
Sample Output
show chassis fpc detail 2
user@host> show chassis fpc detail 2 Slot 2 information: State Online Temperature 37 Total CPU DRAM 1024 MB Total RLDRAM 0 MB Total DDR DRAM 0 MB Start time: 2012-07-18 07:18:50 PDT Uptime: 4 days, 21 hours, 51 minutes, 59 seconds Max Power Consumption 0 Watts
Sample Output
- show chassis fpc pic-status (SRX5600 and SRX5800 devices)
- show chassis fpc pic-status (SRX5600 and SRX5800 devices with SPC2)
- show chassis fpc pic-status (SRX5600 and SRX5800 devices with SRX5K-MPC)
- show chassis fpc pic-status (SRX5600 and SRX5800 devices when Express Path [formerly known as services offloading] is configured)
- show chassis fpc pic-status (with 20-Gigabit Ethernet MIC with SFP)
- show chassis fpc pic-status (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3 and when Express Path [formerly known as services offloading] is configured)
show chassis fpc pic-status (SRX5600 and SRX5800 devices)
user@host> show chassis fpc pic-status Slot 3 Online SRX5k SPC PIC 0 Online SPU Cp PIC 1 Online SPU Flow Slot 6 Online SRX5k DPC 4x 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ
show chassis fpc pic-status (SRX5600 and SRX5800 devices with SPC2)
user@host> show chassis fpc pic-status Slot 0 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 2 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 3 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 5 Online SRX5k SPC PIC 0 Online SPU Flow PIC 1 Online SPU Flow
show chassis fpc pic-status (SRX5600 and SRX5800 devices with SRX5K-MPC)
user@host> show chassis fpc pic-status Slot 0 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 1 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 6 Offline SRX5k SPC II Slot 9 Online SRX5k SPC II PIC 0 Online SPU Flow PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 10 Online SRX5k IOC II PIC 0 Online 10x 10GE SFP+ PIC 2 Online 1x 100GE CFP Slot 11 Online SRX5k IOC II PIC 0 Online 1x 100GE CFP PIC 2 Online 2x 40GE QSFP+
show chassis fpc pic-status (SRX5600 and SRX5800 devices when Express Path [formerly known as services offloading] is configured)
user@host> show chassis fpc pic-status Slot 0 Offline SRX5k DPC 40x 1GE Slot 1 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Offline SRX5k SPC Slot 4 Online SRX5k IOC3 24XGE+6XLG PIC 2 Online 3x 40GE QSFP+- np-cache/services-offload PIC 3 Online 3x 40GE QSFP+- np-cache/services-offload Slot 5 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 1 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 2 Online 10x 10GE SFP+- np-cache/services-offload
show chassis fpc pic-status (with 20-Gigabit Ethernet MIC with SFP)
user@host> show chassis fpc pic-status node0: -------------------------------------------------------------------------- Slot 0 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 1 Offline SRX5k SPC II Slot 2 Online SRX5k DPC 4X 10GE PIC 0 Online 1x 10GE(LAN/WAN) RichQ PIC 1 Online 1x 10GE(LAN/WAN) RichQ PIC 2 Online 1x 10GE(LAN/WAN) RichQ PIC 3 Online 1x 10GE(LAN/WAN) RichQ Slot 9 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP PIC 1 Online 10x 1GE(LAN) SFP PIC 2 Online 10x 1GE(LAN) SFP PIC 3 Online 10x 1GE(LAN) SFP Slot 10 Online SRX5k IOC II PIC 0 Online 10x 10GE SFP+ PIC 2 Online 1x 100GE CFP Slot 11 Offline SRX5k IOC II
show chassis fpc pic-status (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3 and when Express Path [formerly known as services offloading] is configured)
user@host> show chassis fpc pic-status Slot 0 Offline SRX5k DPC 40x 1GE Slot 1 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Online SPU Flow PIC 3 Online SPU Flow Slot 2 Offline SRX5k SPC Slot 4 Online SRX5k IOC3 24XGE+6XLG PIC 2 Online 3x 40GE QSFP+- np-cache/services-offload PIC 3 Online 3x 40GE QSFP+- np-cache/services-offload Slot 5 Online SRX5k IOC II PIC 0 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 1 Online 10x 1GE(LAN) SFP- np-cache/services-offload PIC 2 Online 10x 10GE SFP+- np-cache/services-offload
Sample Output
- show chassis fpc pic-status for HA (SRX5600 and SRX5800 devices)
- show chassis fpc pic-status for HA (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3)
show chassis fpc pic-status for HA (SRX5600 and SRX5800 devices)
user@host> show chassis fpc pic-status node0: ------------------------------------------------------------ Slot 4 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 5 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow node1: -------------------------------------------------------------- Slot 4 Online SRX5k DPC 40x 1GE PIC 0 Online 10x 1GE RichQ PIC 1 Online 10x 1GE RichQ PIC 2 Online 10x 1GE RichQ PIC 3 Online 10x 1GE RichQ Slot 5 Online SRX5k SPC PIC 0 Online SPU Cp-Flow PIC 1 Online SPU Flow
show chassis fpc pic-status for HA (SRX5400, SRX5600, and SRX5800 devices with SRX5K-MPC3-100G10G (IOC3) or SRX5K-MPC3-40G10G (IOC3)
user@host> show chassis fpc pic-status user@host> show chassis fpc pic-status node0: -------------------------------------------------------------------------- Slot 2 Online SRX5k IOC3 24XGE+6XLG PIC 0 Online 12x 10GE SFP+ PIC 1 Online 12x 10GE SFP+ PIC 2 Offline 3x 40GE QSFP+ PIC 3 Offline 3x 40GE QSFP+ Slot 4 Online SRX5k IOC II PIC 2 Online 10x 10GE SFP+ Slot 5 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Offline PIC 3 Offline node1: -------------------------------------------------------------------------- Slot 2 Online SRX5k IOC3 24XGE+6XLG PIC 0 Online 12x 10GE SFP+ PIC 1 Online 12x 10GE SFP+ PIC 2 Offline 3x 40GE QSFP+ PIC 3 Offline 3x 40GE QSFP+ Slot 4 Online SRX5k IOC II PIC 2 Online 10x 10GE SFP+ Slot 5 Online SRX5k SPC II PIC 0 Online SPU Cp PIC 1 Online SPU Flow PIC 2 Offline PIC 3 Offline
Release Information
Command modified in Junos OS Release 9.2.
Starting with Junos OS Release 15.1X49-D10 and Junos OS Release 17.3R1, the SRX5K-MPC3-100G10G (IOC3) and the SRX5K-MPC3-40G10G (IOC3) are introduced.
On SRX5K-MPC3-40G10G (IOC3), all four PICs cannot be powered on. A maximum of two PICs can be powered on at the same time. By default, PIC0 and PIC1 are online.
Use the set chassis fpc <slot> pic <pic> power off
command to choose the PICs you want to power on.
When you use the set chassis fpc <slot> pic <pic>
power off
command to power off PIC0 and PIC1, PIC2 and PIC3
are automatically turned on.
When you switch from one set of PICs to another set of PICs
using the set chassis fpc <slot> pic <pic> power off
command again, ensure that there is 60 seconds duration between
the two actions, otherwise core files are seen during the configuration.
The Table 2 summarizes the SRX5K-MPC3-40G10G (IOC3) PICs selected for various configuration scenarios.
CLI Configuration |
PIC Selection |
---|---|
Default (i.e. no CLI configuration) |
Online: PIC-0, PIC-1 Offline: PIC-2, PIC-3 |
PIC-1, PIC-2 and PIC-3 powered OFF |
Online: PIC-0 Offline: PIC-1, PIC-2, PIC-3 |
PIC-0, PIC-2 and PIC-3 powered OFF |
Online: PIC-1 Offline: PIC-0, PIC-2, PIC-3 |
PIC-0, PIC-1 and PIC-3 powered OFF |
Online: PIC-2 Offline: PIC-0, PIC-1, PIC-3 |
PIC-0, PIC-1 and PIC-2 powered OFF |
Online: PIC-3 Offline: PIC-0, PIC-1, PIC-2 |
PIC-2 and PIC-3 powered OFF |
Online: PIC-0, PIC-1 Offline: PIC-2, PIC-3 |
PIC-2 and PIC-3 powered OFF |
Online: PIC-0, PIC-1 Offline: PIC-2, PIC-3 |
PIC-1 and PIC-2 powered OFF |
Online: PIC-0, PIC-3 Offline: PIC-1, PIC-2 |
PIC-0 and PIC-3 powered OFF |
Online: PIC-2, PIC-1 Offline: PIC-0, PIC-3 |
PIC-0 and PIC-1 powered OFF |
Online: PIC-2, PIC-3 Offline: PIC-0, PIC-1 |
All other combinations of PICs being powered OFF (Invalid) |
Online: PIC-0, PIC-1 Offline: PIC-2, PIC-3 Default PICs will be selected for the invalid combinations. Also, a system log message will be displayed to indicate the invalid combination PIC selection. |