symbol-period
Syntax
symbol-period count;
Hierarchy Level
[edit protocols oam ethernet link-fault-management action-profile name event link-event-rate], [edit protocols oam ethernet link-fault-management interface name [OBSOLETE] event-thresholds]
Description
Configure the threshold for sending symbol period events or taking the action specified in the action profile.
A symbol error is any symbol code error on the underlying physical layer. The symbol period threshold is reached when the number of symbol errors reaches the configured value within the period window. The default period window is the number of symbols that can be transmitted on the underlying physical layer in 1 second. The window is not configurable.
Options
count—Threshold count in seconds for symbol period events.
Range: 0 through 100 seconds
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.
Release Information
Statement introduced in Junos OS Release 9.4.