option-refresh-rate (Services)

date_range 20-Nov-23

Syntax

content_copy zoom_out_map
option-refresh-rate

Hierarchy Level

content_copy zoom_out_map
[edit services flow-monitoring version9 template template-name] 

Description

Specifies the frequency at which the flow generator needs to send the Jflow options template (both template and system scope) to the collector.

Option refresh rate can be configured as number of packets. If the number of packets configured is “n”, it indicates that after every export of “n” data packets to the collector, the options template (both template and system scope) should be exported to the collector.

Option refresh rate can also be configured in seconds. If the seconds configured is “n”, it indicates that after every “n” seconds, the options template (both template and system scope) should be exported to the collector.

The options template provides information such as flow active timeout, flow inactive timeout, sampling interval, and sampling algorithm.

Options

  • packets—Specify the number of packets. The range is from 1 through 480,000.

  • seconds—Specify the number of seconds. The range is from 10 through 600.

Required Privilege Level

services—To view this statement in the configuration.