lowest-priority-defect

Syntax

Hierarchy Level

Description

Specify the lowest priority defect that is allowed to generate a Fault Alarm whenever CFM detects a defect. This configuration is done at the MEP level.

Options

Specify one of the following lowest priority defect options:

all-defects

Allows all defects.

err-xcon

Allows only erroneous CCM and cross-connect CCM defects.

mac-rem-err-xcon

Allows only MAC, not receiving CCM, erroneous CCM, and cross-connect defects.

no-defect

Allows no defects.

rem-err-xcon

Allows only not receiving CCM, erroneous CCM, and cross-connect CCM defects.

xcon

Allows only cross-connect CCM defects.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.0.