show chassis fabric degraded-fabric-reachability
Syntax
show chassis fabric degraded-fabric-reachability
Description
Display the current state of reachability between the Packet Forwarding Engines in the system.
Additional Information
Required Privilege Level
view
Output Fields
Table 1 lists the output
fields for the show chassis fabric degraded-fabric-reachability
command. Output fields are listed in the approximate order in which
they appear.
Field Name |
Field Description |
---|---|
FPC |
Display fabric reachability for the displayed FPC slot. PTX10016 supports 16 FPCs and output detail for each FPC slot. |
PFE |
Display fabric reachability for the displayed PFE slot on a per SIB and plane basis. |
SIBx_Plane y |
Display the SIB (x) and plane (y) where link errors occurred. |
Link errors FPC/PFEs |
Display the list of FPC and PFE slots that are unreachable for the displayed SIB and plane due to link errors. |
Sample Output
show chassis fabric degraded-fabric-reachability
user@host> show chassis fabric degraded-fabric-reachability Degraded Fabric reachability Information: FPC #0 PFE #0 SIB0_Plane 0 Link errors FPC/PFEs 2/0 5/0 5/1 5/2 5/3 SIB0_Plane 1 Link errors FPC/PFEs 2/0 5/0 PFE #1 SIB0_Plane 0 Link errors FPC/PFEs 2/0 5/0 5/1 5/2 5/3 SIB0_Plane 1 Link errors FPC/PFEs 2/0 5/0
Release Information
Command introduced in Junos OS Release 12.1X48R4.