show chassis environment fpm
Syntax
show chassis environment fpm
Syntax (TX Matrix Routers)
show chassis environment fpm <lcc number | scc>
Syntax (TX Matrix Plus Routers)
show chassis environment fpm <lcc number | sfc number>
Description
(M40e, M120, M160, M320, MX Series, and T Series routers and the PTX Series Packet Transport Routers only) Display environmental information about the front panel module in the router.
Options
none | (TX Matrix and TX Matrix Plus routers only) On a TX Matrix router, display environmental information about the front panel modules (craft interfaces) on the TX Matrix router and its attached T640 routers. On a TX Matrix Plus router, display environmental information about the front panel modules (craft interfaces) on the TX Matrix Plus router and its attached routers. |
lcc number | —(TX Matrix router and TX Matrix Plus router only) (Optional) Line-card chassis number. Replace number with the following values depending on the LCC configuration:
|
scc | (TX Matrix router only) (Optional) Display environmental information about the front panel module (craft interface) on the TX Matrix router (or switch-card chassis). |
sfc number | (TX Matrix Plus router only) (Optional) Display environmental information about the front panel module (craft interface) on the TX Matrix Plus router (or switch-fabric chassis). |
Required Privilege Level
view
Output Fields
Table 1 lists the output fields for the show chassis environment
fpm
command. Output fields are listed in the approximate order
in which they appear.
Field Name |
Field Description |
---|---|
State |
FPM status:
|
FPM CMB Voltage |
(M40e and M160 routers only) Information about the voltage supplied to the FPM chassis management bus (CMB) device. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
FPM GBUS Voltage |
(M320 and T Series routers only) Information about the voltage supplied to the FPM generic bus (GBUS) device. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
FPM I2CS Voltage |
(PTX Series only) Information about the voltage supplied to the FPM generic bus (I2CS) device. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
FPM Display Voltage |
Information about the voltage supplied to the FPM display. The left column displays the required power, in volts. The right column displays the measured power, in millivolts. |
FPM CMB Temperature |
(M40e and M160 routers only) Temperature of the air flowing past the FPM CMB device |
FPM GBUS Temperature |
(M320 and T Series routers only) Temperature of the air flowing past the FPM GBUS device. |
FPM I2CS Temperature |
(PTX Series only) Temperature of the air flowing past the FPM I2CS device. |
FPM Display Temperature |
Temperature of the air flowing past the FPM display. |
CMB Revision |
(M40e and M160 routers only) Revision level of the CMB device. |
GBUS Revision |
(M320 and T Series routers only) Revision level of the GBUS device. |
I2CS Revision |
(MX2010 routers, MX2020 routers, MX2008 routers, and PTX Series only) Revision level of the I2CS device. |
Sample Output
- show chassis environment fpm (M40e and M160 Routers)
- show chassis environment fpm (M320 Router)
- show chassis environment fpm (MX2010 Router)
- show chassis environment fpm (MX2020 Router)
- show chassis environment fpm (MX2008 Router)
- show chassis environment fpm (MX240 Router)
- show chassis environment fpm (MX480 Router)
- show chassis environment fpm (T Series Routers)
- show chassis environment fpm lcc (TX Matrix Router)
- show chassis environment fpm scc (TX Matrix Router)
- show chassis environment fpm sfc (TX Matrix Plus Router)
- show chassis environment fpm (T4000 Core Router)
- show chassis environment fpm (PTX5000 Packet Transport Router)
show chassis environment fpm (M40e and M160 Routers)
user@host> show chassis environment fpm FPM status: State Online FPM CMB Voltage: 5.0 V bias 5030 mV 8.0 V bias 8083 mV FPM Display Voltage: 5.0 V bias 4998 mV FPM CMB temperature 34 degrees C / 93 degrees F FPM Display temperature 35 degrees C / 95 degrees F CMB Revision 12
show chassis environment fpm (M320 Router)
user@host> show chassis environment fpm FPM status: State Online FPM GBUS Voltage: 5.0 V 5006 mV 1.8 V bias 1799 mV 3.3 V bias 3294 mV 5.0 V bias 4998 mV 8.0 V bias 7682 mV FPM GBUS temperature 30 degrees C / 86 degrees F GBUS Revision 51
show chassis environment fpm (MX2010 Router)
user@host > show chassis environment fpm FPM status: State Online I2CS Revision 4
show chassis environment fpm (MX2020 Router)
user@host > show chassis environment fpm FPM status: State Online I2CS Revision 3
show chassis environment fpm (MX2008 Router)
user@host > show chassis environment fpm FPM status: State Online I2CS Revision 5
show chassis environment fpm (MX240 Router)
user@host> show chassis environment fpm FPM status: State Online I2CS Revision 41
show chassis environment fpm (MX480 Router)
user@host> show chassis environment fpm FPM status: State Online I2CS Revision 41
show chassis environment fpm (T Series Routers)
user@host> show chassis environment fpm FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1787 mV 3.3 V bias 3286 mV 5.0 V bias 4991 mV 8.0 V bias 7162 mV FPM Display Voltage: 5.0 V 4996 mV FPM GBUS temperature 29 degrees C / 84 degrees F FPM Display temperature 26 degrees C / 78 degrees F GBUS Revision 37
show chassis environment fpm lcc (TX Matrix Router)
user@host> show chassis environment fpm lcc 0 lcc0-re0: -------------------------------------------------------------------------- FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1797 mV 3.3 V bias 3294 mV 5.0 V bias 5015 mV 8.0 V bias 7470 mV FPM Display Voltage: 5.0 V 5018 mV FPM GBUS temperature 25 degrees C / 77 degrees F FPM Display temperature 29 degrees C / 84 degrees F GBUS Revision 37
show chassis environment fpm scc (TX Matrix Router)
user@host> show chassis environment fpm scc scc-re0: -------------------------------------------------------------------------- FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1789 mV 3.3 V bias 3296 mV 5.0 V bias 5003 mV 8.0 V bias 7592 mV FPM Display Voltage: 5.0 V 5010 mV FPM GBUS temperature 22 degrees C / 71 degrees F FPM Display temperature 27 degrees C / 80 degrees F GBUS Revision 37
show chassis environment fpm sfc (TX Matrix Plus Router)
user@host> show chassis environment fpm sfc sfc0-re0: -------------------------------------------------------------------------- FPM status: State Online FPM I2CS Voltage: 3.3 V 3300 mV 5.0 V 5001 mV 9.0 V FPD 8672 mV FPM I2CS temperature 33 degrees C / 91 degrees F I2CS Revision 69 lcc0-re0: -------------------------------------------------------------------------- FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1802 mV 3.3 V bias 3301 mV 5.0 V bias 4984 mV 8.0 V bias 7377 mV FPM Display Voltage: 5.0 V 5015 mV FPM GBUS temperature 30 degrees C / 86 degrees F FPM Display temperature 32 degrees C / 89 degrees F GBUS Revision 37 lcc1-re0: -------------------------------------------------------------------------- FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1789 mV 3.3 V bias 3311 mV 5.0 V bias 5013 mV 8.0 V bias 7467 mV FPM Display Voltage: 5.0 V 5015 mV FPM GBUS temperature 29 degrees C / 84 degrees F FPM Display temperature 31 degrees C / 87 degrees F GBUS Revision 37
show chassis environment fpm (T4000 Core Router)
user@host> show chassis environment fpm CB 0 status: State Online Master Temperature 34 degrees C / 93 degrees F Power 1 1.8 V 1804 mV 2.5 V 2499 mV 3.3 V 3317 mV 3.3 V bias 3291 mV 4.6 V 4663 mV 5.0 V 4905 mV 8.0 V bias 7658 mV 12.0 V 11877 mV Power 2 1.0 V 996 mV 1.2 V 1207 mV 3.3 V RE 3354 mV Bus Revision 51 FPGA Revision 5 CB 1 status: State Online Standby Temperature 36 degrees C / 96 degrees F Power 1 1.8 V 1791 mV 2.5 V 2494 mV 3.3 V 3321 mV 3.3 V bias 3301 mV 4.6 V 4666 mV 5.0 V 4945 mV 8.0 V bias 7645 mV 12.0 V 11897 mV Power 2 1.0 V 991 mV 1.2 V 1201 mV 3.3 V RE 3289 mV Bus Revision 51 FPGA Revision 5 user@host> show chassis environment fpm FPM status: State Online FPM GBUS Voltage: 1.8 V bias 1802 mV 3.3 V bias 3294 mV 5.0 V bias 5003 mV 8.0 V bias 7306 mV FPM Display Voltage: 5.0 V 5010 mV FPM GBUS temperature 26 degrees C / 78 degrees F FPM Display temperature 29 degrees C / 84 degrees F GBUS Revision 37
show chassis environment fpm (PTX5000 Packet Transport Router)
user@host> show chassis environment fpm FPM status: State Online FPM I2CS Voltage: 3.3 V 3300 mV 5.0 V 4975 mV FPM I2CS temperature 37 degrees C / 98 degrees F I2CS Revision 109
Release Information
Command introduced before Junos OS Release 7.4.
sfc option introduced for the TX Matrix Plus router in Junos OS Release 9.6.